4 FREQUENCY PROGRAMMING
4 Frequency Programming
Channel and tone frequency programming is most easily acomplished with RF
Technology TecHelp/Service Monitor 2000 software. This software can be run on
an IBMcompatible/Windows PC and provides a number of additional useful
facillities.
TecHelp/Service Monitor 2000 allows setting of the adaptive noise squelch
threshold, provides a simple means of calibrating the signal strength output and
minimum signal alarm.
TecHelp/Service Monitor 2000 can be supplied by your dealer, distributor or by
contacting RF Technology direct.
5 Circuit Description
The following descriptions should be read as an aid to understanding the block and
schematic diagrams at the rear of this manual.
5.1 RF Section
A two pole voltage tuned filter (D13, D14, L35-39) is used to limit the RF band
width prior to the RF amplifier transistor Q1. The tuning voltage is supplied by the
frequency synthesizer through voltage follower U28D. The circuit values are chosen
so that the centre frequency tracks the VCO frequency.
RF amplifier transistor Q1 is followed by a second two pole voltage tuned filter
(D15, D16, L28-32) which provides additional image and spurious frequency
rejection. The filter output is connected to the RF input port of the mixer MX1.
MX1 is a high level double balanced diode ring mixer with excellent inter-
modulation performance. It has a conversion loss of approximately 6 dB. The gain
between the receiver input and the mixer input is approximately 10 dB so that the
total gain between the antenna input and the IF input 3-4dB.
Monolithic amplifiers MA1, MA2 and transistor Q5 amplify the VCO output to the
necessary LO level for MX1 approximately +13dBm.
The network C8, C9 L1-3 and R6 passes the IF frequency of 45 MHz and terminates
the RF and LO components.
5.2 IF Section
The first IF amplifier uses two parallel connected JFET transistors Q2 and Q3 to
obtain 8-10 dB gain. The two transistors provide improved dynamic range and input
matching over a single transistor.
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 26 27

Kommentare zu diesen Handbüchern

Keine Kommentare

Daikin WMC manuales

Manuales del propietario y guías del usuario para Pequeños Utensilios De Cocina Daikin WMC.
Ofrecemos 3 manuales en pdf Daikin WMC para descargar gratis por tipos de documentos: Especificaciones, Manual de instrucciones


Tabla de contenidos

Model WMC, C Vintage

1

HFC-134a Refrigerant

1

50/60 Hz

1

Table of ConTenTs

2

InTroduCTIon

3

General Description

4

W M C 290 D CS

4

The Control System

5

Receiving and Handling

6

Nameplates

6

Location

6

Clearance

6

Mounting

8

Water Piping

8

Vessel Drains at Startup

8

Condenser Water

9

Temperature Control

9

Relief Valves

10

Field Insulation

11

Field Power Wiring

11



12



12

 

13



14

InsTallaTIon

16

Communication Setup for

18

Multiple Chillers

18

Long Term Storage

18

Pre-Start Checklist

19

Operator Responsibilities

20

Operator Schools

20

Sequence of Unit Operation

20

Unit Enabling/Disabling

20

Operator Interface Touch

21

Screen (OITS)

21

VIEW Screens

22

Detail View Screen

23

View Menu Screen

25

SET Screens

26

Explanation of Setpoints

27

TIMERS Setpoints

28

ALARMS Setpoints

29

Cooling TOWER Fan Setpoints

31

Fan Stages

32

VFD Speed (%)

33

CAUTION

35

MOTOR Setpoint Screen

36

Compressor Capacity Control

37

Capacity Overrides

37

MODES Setpoints

38

WATER Setpoints

39

Service Screen

40

HISTORY Screens

41

Alarm History Screen

42

Active Alarms Screen

43

Possible Alarms and Events

44

MODEL WMC CHILLERS

45

Problem Alarms

46

Warning Alarms

46

The Controller

48

Menu Structure (Scrolled)

49

VIEW UNIT VIEW COMPRESSOR

50

EVAPORATOR

50

Setting Passwords

52

Conguring the Control Source

53

Clearing Alarms

53

Controller Inputs and Outputs

54

Controller Setpoints

55

IOM 1210-1 • MAGNITUDE

56

Building Automation

58

Systems (BAS)

58

Use with On-Site Generators

58

Service Programs

59

Chiller Maintenance

59

Seasonal Shutdown

59

Seasonal Startup

59

Maintenance Schedule

60

Denitions

61

Temperature / Pressure Chart

64





Más productos y manuales para Pequeños Utensilios De Cocina Daikin

Modelos Tipo de documento
WGZ030DW Especificaciones   Daikin WGZ030DW Specifications, 88 paginas
AGZ030EH Manual de instalación   Daikin AGZ030EH Unit installation, 78 paginas
AGZ 040D Manual de usuario   RPL: AGZ 025-190 Vintage D, Unit Rev. 00 and 0A [en] , 82 paginas